Entwurf

Changelog

GHS [M212]

Eigenschaft Wert
M-Nummer M212
BMS ID 3087
GDSN Attributname regulatoryPermitIdentification
Zusätzliche BMS IDs 3071
Zusätzliche GDSN Attributnamen regulatoryAct
Datenelementgruppe GHS-Angaben
Datenelementuntergruppe -
xml path & SET-Anweisungen Case 1: GHS = YES SET regulated_trade_item:regulatedTradeItemModule/regulatoryInformation/permitIdentification/regulatoryPermitIdentification = TRUE SET regulated_trade_item:regulatedTradeItemModule/regulatoryInformation/regulatoryAgency = UN SET regulated_trade_item:regulatedTradeItemModule/regulatoryInformation/regulatoryAct = GHS Case 2: GHS = NO SET regulated_trade_item:regulatedTradeItemModule/regulatoryInformation/permitIdentification/regulatoryPermitIdentification = FALSE SET regulated_trade_item:regulatedTradeItemModule/regulatoryInformation/regulatoryAgency = UN SET regulated_trade_item:regulatedTradeItemModule/regulatoryInformation/regulatoryAct = GHS
Hierarchieebene Lowest level
Format Non-Binary Logic Defined values
Ausprägung / Wertebereich TRUE, FALSE
Codeliste NonBinaryLogicEnumeration
Wiederholbarkeit NO
Wiederholbarkeit in Gruppe -
Multi Sprache Maßeinheit Währung
Komponenten
Pfandinformation
Triggerelement true
Verpackungsbezug
In diesem Attribut werden ausschließlich
Angaben erwartet, die sich auf der Produktverpackung finden
false
Verpackungsbezug_Ausnahme

Status

StatusZielmarktProfil
MDEFMCG
-DEHC
MDEDIY

Definition

Angabe, ob der Artikel gemäß GHS und der entsprechenden nationalen Umsetzung eingestuft und gekennzeichnet ist oder nicht.

Ergänzende Community Beschreibung

./.

Bedingungen und Verknüpfungen

Diese Angabe muss bzw. sollte immer angegeben werden, außer wenn es sich um Pfandartikel Leergut handelt ( Ist der Pfandartikel Leergut [M357] = Ja (true)) oder wenn Rechtliche Produktkategorie [M250] = MEDICAL_DEVICE_SAFETY (= Medizinprodukt).GHS-Angaben

Weitere Attribute in diesem Zusammenang

./.


Sichtprüfungsrelevant

Nein

Validierungsregeln

ID Bedingung Logik
VR100118Wenn " Basisartikel [M243] " = "true" und " GPC Brick [M317] " entspricht GPC Matrix und " GHS [M212] " gefüllt istdann muss " GHS [M212] " = "FALSE" sein
VR100135Wenn " Basisartikel [M243] " = "true" und " GPC Brick [M317] " entspricht GPC Matrixdann muss " GHS [M212] " = "TRUE" sein
ID Bedingung Logik
VR000153Wenn " Basisartikel [M243] " = "true" und " Verpackungsart [M286] " = "AE" ist und " Nettofüllmenge / Maßeinheit [M281] " >= 125 ml und " GPC Brick [M317] " entspricht GPC Matrixdann muss " Gefahrgut [M187] " = "ZCG" und " GHS [M212] " = "TRUE" sein
VR001941Wenn " Basisartikel [M243] " = "true" und " GHS [M212] " ungleich "TRUE" und " AGRO-Artikel [M1129] " ungleich "true" und " Rechtliche Produktkategorie [M250] " = "DETERGENTS_SAFETY_REGULATION"dann muss " Kontaktname Inverkehrbringer [M370] " gefüllt sein
VR001942Wenn " Basisartikel [M243] " = "true" und " GHS [M212] " ungleich "TRUE" und " AGRO-Artikel [M1129] " ungleich "true" und " Rechtliche Produktkategorie [M250] " = "DETERGENTS_SAFETY_REGULATION"dann muss " Kontaktadresse Inverkehrbringer [M371] " gefüllt sein
VR001945Wenn " Basisartikel [M243] " = "true" und " GHS [M212] " ungleich "TRUE" und " Rechtliche Produktkategorie [M250] " = ["SECURITY_OF_ELECTRONIC_PRODUCTS_DIRECTIVE" oder "TOY_SAFETY_DIRECTIVE" oder "INTENDED_TO_COME_INTO_CONTACT_WITH_FOOD"]dann muss " Kontaktname Inverkehrbringer [M370] " gefüllt sein
VR001946Wenn " Basisartikel [M243] " = "true" und " GHS [M212] " ungleich "TRUE" und " Rechtliche Produktkategorie [M250] " = ["SECURITY_OF_ELECTRONIC_PRODUCTS_DIRECTIVE" oder "TOY_SAFETY_DIRECTIVE" oder "INTENDED_TO_COME_INTO_CONTACT_WITH_FOOD"]dann muss " Kontaktadresse Inverkehrbringer [M371] " gefüllt sein
VR001947Wenn " Basisartikel [M243] " = "true" und " GHS [M212] " ungleich "TRUE" und " HEALTHCARE-Artikel [M3000] " ungleich "true" und " Rechtliche Produktkategorie [M250] " = ["MEDICAL_DEVICE_SAFETY" oder "FREE_PHARMACEUTICAL_PRODUCTS_DIRECTIVE" oder "PHARMACEUTICAL_PRODUCT_DIRECTIVE" oder "FOOD_SUPPLEMENT_DIRECTIVE"]dann muss " Kontaktname Inverkehrbringer [M370] " gefüllt sein
VR001948Wenn " Basisartikel [M243] " = "true" und " GHS [M212] " ungleich "TRUE" und " HEALTHCARE-Artikel [M3000] " ungleich "true" und " Rechtliche Produktkategorie [M250] " = ["MEDICAL_DEVICE_SAFETY" oder "FREE_PHARMACEUTICAL_PRODUCTS_DIRECTIVE" oder "PHARMACEUTICAL_PRODUCT_DIRECTIVE" oder "FOOD_SUPPLEMENT_DIRECTIVE"]dann muss " Kontaktadresse Inverkehrbringer [M371] " gefüllt sein
VR100096Wenn " Basisartikel [M243] " = "true" und " GHS Piktogramme [M215] " 1x gefüllt und = "ENVIRONMENT" ist und " GHS Signalwort Code [M218] " gefüllt istdann muss " GHS Signalwort Code [M218] " = "WARNING" oder "NOT_APPLICABLE" sein
VR100098Wenn " Basisartikel [M243] " = "true" und " GHS Piktogramme [M215] " 1x gefüllt und = "GAS_CYLINDER" ist und " GHS Signalwort Code [M218] " gefüllt istdann muss " GHS Signalwort Code [M218] " = "WARNING" sein
VR100099Wenn " Basisartikel [M243] " = "true" und " GHS Piktogramme [M215] " 1x gefüllt und = "EXCLAMATION_MARK" ist und " GHS Signalwort Code [M218] " gefüllt istdann muss " GHS Signalwort Code [M218] " = "WARNING" sein
VR100100Wenn " Basisartikel [M243] " = "true" und " GHS Piktogramme [M215] " 1x gefüllt und = "SKULL_AND_CROSSBONES" ist und " GHS Signalwort Code [M218] " gefüllt istdann muss " GHS Signalwort Code [M218] " = "DANGER" sein
VR100106Wenn " Basisartikel [M243] " = "true" und " GHS [M212] " = "TRUE" und " GPC Brick [M317] " entspricht GPC Matrix und " AGRO-Artikel [M1129] " ungleich "true"dann muss " Kontaktname Inverkehrbringer [M370] " gefüllt sein
VR100107Wenn " Basisartikel [M243] " = "true" und " GHS [M212] " = "TRUE" und " GPC Brick [M317] " entspricht GPC Matrix und " AGRO-Artikel [M1129] " ungleich "true"dann muss " Kontaktadresse Inverkehrbringer [M371] " gefüllt sein
VR100108Wenn " Basisartikel [M243] " = "true" und " GHS [M212] " = "TRUE" und " AGRO-Artikel [M1129] " ungleich "true" istdann muss " Kommunikationskanal: Code [M377] " = ["TELEPHONE" oder "TELEPHONE_FREE_NUMBER"] enthalten
ID Fehlermeldung
ID Fehlermeldung
321244Bitte machen Sie eine Angabe zu {propertyReference,scope}. Diese Angabe ist verpflichtend.
ID Fehlermeldung
ID Fehlermeldung